Interim and temporary removable dentures fabricated in our Shenzhen and Huizhou labs. Heat-cured, injection-molded, or 3D-printed bases; full-arch, partial, and overdenture cases; reline, rebase, add-tooth, and repair services. Digital or physical impressions accepted. Send Rx → receive finished case.

Temporary Denture Specifications 

Field

Detail

Product name

Interim / Temporary Removable Denture

Case types

Full-arch, partial, overdenture (tissue- or implant-supported interim), repair and reline

Base materials

Heat-cured PMMA, self-cured PMMA, injection-molded PMMA, 3D-printed denture resin

Artificial teeth

Composite resin, acrylic resin, porcelain

Tooth setup

Wax try-in or setup approval available for full-arch cases

Attachments supported

Ball, bar, locators (generic attachment housings per Rx)

Materials traceability

Lot, brand, country of origin, CoA per case on request

Impression formats (digital)

STL, PLY, OBJ, DCM, 3OXZ

Recommended impression materials (physical)

VPS (polyvinyl siloxane) or polyether

Bite registration

Hard silicone or articulator transfer — wax records not recommended

Lab turnaround

Working days from complete case receipt (see Turnaround)

Indications

Pre-extraction transition, post-extraction healing period, implant integration period, staged reconstruction, tissue shaping prior to definitive prosthesis

Temporary Dentures: Indications and Use Cases

Interim dentures serve as transitional prostheses during multi-stage treatment. Common indications:

  • Post-extraction transition — Replacement of teeth lost to extraction or trauma while definitive treatment is planned
  • Implant integration period — Interim prosthesis that does not load the implant site; temporary partial denture designs accommodate localized edentulous areas adjacent to healing implants
  • Staged reconstruction — Verification of VDO, CR, and smile line before definitive restoration
  • Tissue conditioning — Shaping soft tissue contour prior to the definitive prosthesis
  • Acute tooth loss — Immediate replacement following emergency extraction or avulsion

Temporary Denture Materials and Fabrication Methods 

Base Materials

Route

Material

Indication

Trade-off

Heat-cured

Heat-cured PMMA

Standard cases, extended transitional wear

High strength, stable polymerization; longer cycle

Self-cured

Self-cured PMMA

Emergency cases, chairside repair

Fast turnaround; higher residual monomer, lower long-term comfort

Injection-molded

Injection PMMA

High-precision cases, tissue-surface accuracy requirements

Low shrinkage, high tissue-surface adaptation; higher equipment and material cost

3D-printed

Digital denture resin

Digital workflow, rush cases, individualized morphology

Fast, reproducible; long-term strength data still accruing

Artificial Teeth

Three categories available: composite resin teeth, acrylic resin teeth, porcelain teeth. Selection is made per case based on occlusal load, esthetic requirements, and patient allergy history. Composite and acrylic teeth chemically bond to the base; porcelain teeth require mechanical retention.

Brand Specification

Brand and lot number can be specified on the Rx. Stock brands include Lucitone 199 (Dentsply Sirona import) and other heat-cured PMMA sources. Domestic heat-cured PMMA also available. Lot, brand, country of origin, and CoA provided per case on request.

Processing Parameters and In-Process Controls

Packing and Curing

  • Powder-liquid ratio and dough-stage packing: per material manufacturer’s specification; excess monomer avoided
  • Stepped temperature-increase water bath polymerization; rapid heating avoided
  • Slow cooling in water bath; no quench cooling — quench cooling increases internal stress and warpage
  • Flask pressure maintained during pack stage

Injection-Molding Parameters

Cure profile (temperature, pressure, hold time) follows material manufacturer’s recommended curve. Post-cure base dimensions measured against CAD data to assess deformation.

Base Thickness

Verified with calipers at load-bearing and border regions. Minimum cross-section per material type and load requirement; cases below threshold are not released.

Transmission Inspection

Internal porosity and crack inspection under transmitted light after cure. Cases with visible porosity or cracks are not released.

Polishing and Border Control

Tissue surface receives light polish only — over-polishing alters surface morphology and adaptation. Borders and clasps receive standard polish.

Case Submission

Digital Cases

  • Accepted formats: STL, PLY, OBJ, DCM, 3OXZ
  • Color scans: PLY
  • Upload via encrypted link (case-ID per lab convention)
  • File naming convention provided on request

Physical Cases

  • Impression materials: VPS or polyether
  • Bite registration: hard silicone or articulator transfer (wax records not recommended — deformation risk in transit)
  • Disinfect impressions and models per local regulation before shipment

Required Clinical Records

Record

Notes

Impression or scan data

—

Bite registration

VDO / CR

Shade information

—

Clinical photographs

When applicable

Rx

Interim type, intended wear period, special requirements

Cases with incomplete records are confirmed with the sender before fabrication begins.

Wax Try-In and Setup Approval

Full-arch interim cases pass through wax try-in or setup before packing:

  • Before approval — tooth arrangement, base contour, jaw relation adjustable
  • After approval — limited modifications; major changes require new wax-up

Turnaround

  • Calculated in working days from receipt of complete records; calendar days not used
  • Design approval, client response time, and record-supplementation time excluded
  • International transit and customs clearance time excluded
  • Weekends and Chinese statutory holidays excluded
  • Rush cases accepted with prior notice; subject to case-complexity review

Quality Control and Rework Policy

Four-Stage Inspection

  1. Model stage — impression or scan completeness
  2. Wax-up stage — jaw relation and tooth arrangement
  3. Setup stage — esthetics and occlusion
  4. Final cure inspection — base adaptation, tooth retention, border polish

Free Rework Scope

Included: does not seat, lifts at border, clasp design inadequate, occlusion inaccurate, shade does not match Rx.

Cases outside the free-rework scope are agreed with the sender before fabrication.

Compliance and Traceability

Item

Detail

Quality system

ISO 13485

Material compliance

CE (material side)

EU custom-made devices

MDR Annex XIII notification process

Material traceability

Lot, brand, country of origin, CoA per case

Case traceability

Technician, equipment, material lot, QC record retained per case

Material-side test standards documented per shipment; technical file available on request.

Interim Denture Coordination with Implant and Fixed Prostheses 

  • Implant integration period — interim partial does not load the implant site
  • Immediate-load temporary bridge — fabrication supported per implant Rx
  • Tissue-shaping phase — interim fabricated to definitive design parameters for soft-tissue contour transfer
  • Multi-stage case planning — phase-specific interim fabrication per treatment plan

Ordering Information

Item

Detail

Single-case trial order

Accepted

Digital submission

STL / PLY / OBJ via encrypted upload

Physical shipment

Shipping waybill and disinfection guidance provided on request

Account contact

Dedicated account manager + case coordinator per client

Working language

English for case communication and technical meetings

Agreements

NDA, quality agreement, supplier agreement available

Vendor onboarding

Onboarding questionnaire and annual audit supported

Lab at a Glance

Item

Detail

Established

2012

Facilities

Shenzhen and Huizhou (two sites)

Headcount

~460 employees across CAD, milling, implant, ceramic & metal, removable, QC, admin, sales, customer service

Removable denture department

~55 staff

Removable capacity

4,000 cases / month (low season) — 6,500 cases / month (peak season)

Workflow

In-house only; no third-party outsourcing

Clients served

50+ dental labs, 100+ clinics, 400+ dentists

Primary markets

United States, Netherlands, Germany, France, Belgium, Austria, United Kingdom, Luxembourg, Switzerland

Site visit

Factory tour and video audit available on request

Frequently Asked Questions

In professional literature, interim denture emphasizes the transitional role within a treatment sequence. Temporary is the term more commonly used on prescriptions and insurance documents. The fabrication requirements are identical.

An immediate denture is placed on the day of extraction; temporary denture is the broader category covering any prosthesis designed to be replaced.

Yes. Brand, lot, and country of origin noted on Rx; procurement and CoA provided per case.

Digital eliminates shipping and model-scanning steps; preferred for time-sensitive cases. Physical impressions remain appropriate where impression detail or bite relation needs direct observation.

Does-not-seat, border lift, inadequate clasp design, inaccurate occlusion, shade mismatch with Rx. Out-of-scope cases agreed before fabrication.

Experience faster turnaround times with our cutting-edge technology

Experience faster turnaround times with our cutting-edge technology