Temporary Dentures — Interim Denture Lab Services
Interim and temporary removable dentures fabricated in our Shenzhen and Huizhou labs. Heat-cured, injection-molded, or 3D-printed bases; full-arch, partial, and overdenture cases; reline, rebase, add-tooth, and repair services. Digital or physical impressions accepted. Send Rx → receive finished case.
Temporary Denture Specifications
Field | Detail |
Product name | Interim / Temporary Removable Denture |
Case types | Full-arch, partial, overdenture (tissue- or implant-supported interim), repair and reline |
Base materials | Heat-cured PMMA, self-cured PMMA, injection-molded PMMA, 3D-printed denture resin |
Artificial teeth | Composite resin, acrylic resin, porcelain |
Tooth setup | Wax try-in or setup approval available for full-arch cases |
Attachments supported | Ball, bar, locators (generic attachment housings per Rx) |
Materials traceability | Lot, brand, country of origin, CoA per case on request |
Impression formats (digital) | STL, PLY, OBJ, DCM, 3OXZ |
Recommended impression materials (physical) | VPS (polyvinyl siloxane) or polyether |
Bite registration | Hard silicone or articulator transfer — wax records not recommended |
Lab turnaround | Working days from complete case receipt (see Turnaround) |
Indications | Pre-extraction transition, post-extraction healing period, implant integration period, staged reconstruction, tissue shaping prior to definitive prosthesis |
Temporary Dentures: Indications and Use Cases
Interim dentures serve as transitional prostheses during multi-stage treatment. Common indications:
- Post-extraction transition — Replacement of teeth lost to extraction or trauma while definitive treatment is planned
- Implant integration period — Interim prosthesis that does not load the implant site; temporary partial denture designs accommodate localized edentulous areas adjacent to healing implants
- Staged reconstruction — Verification of VDO, CR, and smile line before definitive restoration
- Tissue conditioning — Shaping soft tissue contour prior to the definitive prosthesis
- Acute tooth loss — Immediate replacement following emergency extraction or avulsion
Temporary Denture Materials and Fabrication Methods
Base Materials
Route | Material | Indication | Trade-off |
Heat-cured | Heat-cured PMMA | Standard cases, extended transitional wear | High strength, stable polymerization; longer cycle |
Self-cured | Self-cured PMMA | Emergency cases, chairside repair | Fast turnaround; higher residual monomer, lower long-term comfort |
Injection-molded | Injection PMMA | High-precision cases, tissue-surface accuracy requirements | Low shrinkage, high tissue-surface adaptation; higher equipment and material cost |
3D-printed | Digital denture resin | Digital workflow, rush cases, individualized morphology | Fast, reproducible; long-term strength data still accruing |
Artificial Teeth
Three categories available: composite resin teeth, acrylic resin teeth, porcelain teeth. Selection is made per case based on occlusal load, esthetic requirements, and patient allergy history. Composite and acrylic teeth chemically bond to the base; porcelain teeth require mechanical retention.
Brand Specification
Brand and lot number can be specified on the Rx. Stock brands include Lucitone 199 (Dentsply Sirona import) and other heat-cured PMMA sources. Domestic heat-cured PMMA also available. Lot, brand, country of origin, and CoA provided per case on request.
Processing Parameters and In-Process Controls
Packing and Curing
- Powder-liquid ratio and dough-stage packing: per material manufacturer’s specification; excess monomer avoided
- Stepped temperature-increase water bath polymerization; rapid heating avoided
- Slow cooling in water bath; no quench cooling — quench cooling increases internal stress and warpage
- Flask pressure maintained during pack stage
Injection-Molding Parameters
Cure profile (temperature, pressure, hold time) follows material manufacturer’s recommended curve. Post-cure base dimensions measured against CAD data to assess deformation.
Base Thickness
Verified with calipers at load-bearing and border regions. Minimum cross-section per material type and load requirement; cases below threshold are not released.
Transmission Inspection
Internal porosity and crack inspection under transmitted light after cure. Cases with visible porosity or cracks are not released.
Polishing and Border Control
Tissue surface receives light polish only — over-polishing alters surface morphology and adaptation. Borders and clasps receive standard polish.
Case Submission
Digital Cases
- Accepted formats: STL, PLY, OBJ, DCM, 3OXZ
- Color scans: PLY
- Upload via encrypted link (case-ID per lab convention)
- File naming convention provided on request
Physical Cases
- Impression materials: VPS or polyether
- Bite registration: hard silicone or articulator transfer (wax records not recommended — deformation risk in transit)
- Disinfect impressions and models per local regulation before shipment
Required Clinical Records
Record | Notes |
Impression or scan data | — |
Bite registration | VDO / CR |
Shade information | — |
Clinical photographs | When applicable |
Rx | Interim type, intended wear period, special requirements |
Cases with incomplete records are confirmed with the sender before fabrication begins.
Wax Try-In and Setup Approval
Full-arch interim cases pass through wax try-in or setup before packing:
- Before approval — tooth arrangement, base contour, jaw relation adjustable
- After approval — limited modifications; major changes require new wax-up
Turnaround
- Calculated in working days from receipt of complete records; calendar days not used
- Design approval, client response time, and record-supplementation time excluded
- International transit and customs clearance time excluded
- Weekends and Chinese statutory holidays excluded
- Rush cases accepted with prior notice; subject to case-complexity review
Quality Control and Rework Policy
Four-Stage Inspection
- Model stage — impression or scan completeness
- Wax-up stage — jaw relation and tooth arrangement
- Setup stage — esthetics and occlusion
- Final cure inspection — base adaptation, tooth retention, border polish
Free Rework Scope
Included: does not seat, lifts at border, clasp design inadequate, occlusion inaccurate, shade does not match Rx.
Cases outside the free-rework scope are agreed with the sender before fabrication.
Compliance and Traceability
Item | Detail |
Quality system | ISO 13485 |
Material compliance | CE (material side) |
EU custom-made devices | MDR Annex XIII notification process |
Material traceability | Lot, brand, country of origin, CoA per case |
Case traceability | Technician, equipment, material lot, QC record retained per case |
Material-side test standards documented per shipment; technical file available on request.
Interim Denture Coordination with Implant and Fixed Prostheses
- Implant integration period — interim partial does not load the implant site
- Immediate-load temporary bridge — fabrication supported per implant Rx
- Tissue-shaping phase — interim fabricated to definitive design parameters for soft-tissue contour transfer
- Multi-stage case planning — phase-specific interim fabrication per treatment plan
Ordering Information
Item | Detail |
Single-case trial order | Accepted |
Digital submission | STL / PLY / OBJ via encrypted upload |
Physical shipment | Shipping waybill and disinfection guidance provided on request |
Account contact | Dedicated account manager + case coordinator per client |
Working language | English for case communication and technical meetings |
Agreements | NDA, quality agreement, supplier agreement available |
Vendor onboarding | Onboarding questionnaire and annual audit supported |
Lab at a Glance
Item | Detail |
Established | 2012 |
Facilities | Shenzhen and Huizhou (two sites) |
Headcount | ~460 employees across CAD, milling, implant, ceramic & metal, removable, QC, admin, sales, customer service |
Removable denture department | ~55 staff |
Removable capacity | 4,000 cases / month (low season) — 6,500 cases / month (peak season) |
Workflow | In-house only; no third-party outsourcing |
Clients served | 50+ dental labs, 100+ clinics, 400+ dentists |
Primary markets | United States, Netherlands, Germany, France, Belgium, Austria, United Kingdom, Luxembourg, Switzerland |
Site visit | Factory tour and video audit available on request |
Frequently Asked Questions
In professional literature, interim denture emphasizes the transitional role within a treatment sequence. Temporary is the term more commonly used on prescriptions and insurance documents. The fabrication requirements are identical.
An immediate denture is placed on the day of extraction; temporary denture is the broader category covering any prosthesis designed to be replaced.
Yes. Brand, lot, and country of origin noted on Rx; procurement and CoA provided per case.
Digital eliminates shipping and model-scanning steps; preferred for time-sensitive cases. Physical impressions remain appropriate where impression detail or bite relation needs direct observation.
Does-not-seat, border lift, inadequate clasp design, inaccurate occlusion, shade mismatch with Rx. Out-of-scope cases agreed before fabrication.