Don't Close It In A Hurry, Contact The Boss Directly And Reply In 30 Minutes

Experience faster turnaround times with our cutting-edge technology

Premolar and Molar Implant

🕢 [ Fill out the form and we will respond within 30 minutes! ]

Advanced Posterior Implant System for Dental Professionals

Are you looking for top-quality posterior tooth replacement solutions? ASD Dental Lab brings you a biomechanically superior premolar and molar implant system. Our implants help you give your patients the best care. We made this for dental pros like you – not for patients.

Our precision-engineered implants work with your current systems. They help you fix missing back teeth fast. With our implants, you spend less time in the chair and get better results. We ship to clinics and labs in 48 hours.

Technical Specifications and Design Features

Our premolar and molar implants are made for the tough job of back teeth. They handle big bites and last a long time.

FeatureSpecificationBenefit
MaterialGrade 5 titanium-zirconia hybridBetter strength where you need it most
Diameter Range4.1mm – 6.0mmFits all kinds of bone width
Max Torque35NcmStays put when you place it
Angle Options±25° adjustableSkip sinus lifts in many cases
SurfaceSand+acid treated (Ra=1.5μm)Bone sticks to it fast
Platform Design0.3mm offsetKeeps bone level high
Digital ReadyWorks with 3Shape®/CEREC®Fast digital workflow
Safety StandardsFDA and CE certifiedSafe for all patients

Why Our Posterior Implants Beat the Rest

Perfect Fit for Hard-to-Reach Areas

Back teeth can be hard to work on. Our implants have special thread design that helps them grip bone better. This works great in Type III/IV bone. The threads are made to cut in fast and stay put.

The tips have a tapered apex that makes first placement easy. You can place these even when space is tight. And the triple-lead threads mean fewer turns to get them in place.

Our platform switching design keeps bone loss tiny – less than 0.2mm each year. This makes the gums look better and last longer.

Works With Your Current Systems

You don’t need all new tools! Our implants work with what you already have. They fit with Nobel Biocare® and Straumann® systems.

Each implant comes with:

  • Pre-mounted scan bodies for digital scans
  • Multi-unit abutments that fit right away
  • Comfort caps for healing time
  • Lab analogs for your technicians

ASD Dental Lab makes sure you can use your current CAD/CAM systems with our implants. Just scan and go!

Best-in-Class Stress Distribution

Back teeth take big bites. Our implants have stress-breaking connectors that spread out the force. This helps the bone stay healthy longer.

The 3Y-TZP zirconia parts mix with titanium to give you the best of both. The zirconia looks like real teeth, and the titanium is super strong.

Tests show our implants handle occlusal load distribution better than most. They use posterior implant biomechanics science to prevent breaks and cracks.

Ordering and Implementation Guide

Fast Digital Workflow

  1. Send us your CBCT scans or STL files
  2. We help plan the best implant size
  3. You get the parts in 48 hours
  4. Place the implant with your current tools
  5. Use the scan bodies to make the crown
  6. Finish with our custom abutments

Our full implant prosthetics ship fast and work right away.

Benefits for Your Practice

  • Less chair time means more patients each day
  • Fewer fails means happier patients
  • Works with current tools means no big new costs
  • Digital workflow makes everything faster
  • ISO 13485-certified means top quality always

Customer Reviews and Case Studies

“The premolar implants from ASD Dental Lab cut my chair time by 30%. The thread design makes placement smooth even in soft bone.” – Dr. L. Zhang, Implantologist

“We’ve placed over 200 of these molar implants with a 99.2% success rate. The platform switching design keeps bone levels stable year after year.” – Dental Clinic Director

“The digital workflow is perfect. From scan to final crown in just 5 days total. My lab loves the compatibility.” – Dr. R. Chen, Prosthodontist

Technical Details for Advanced Users

For those who want the deep details, here’s more:

  • Implant-abutment microgap: Less than 10μm for best bacterial seal
  • Abutment screw preload: Optimized to prevent loosening
  • Thermal cycling resistance: Tested to 10,000 cycles
  • Resonance frequency analysis: ISQ values >70 in normal bone
  • Cantilever mechanics: Safe up to 8mm with proper planning

We test all implants with ISO 14801 fatigue testing to make sure they last. Our torque value optimization meets all industry standards.

With ASD Dental Lab’s premolar and molar implants, you get the best posterior tooth replacements. Our molar implant solutions work with your current systems and make your job easier.

Order today and see why top dental pros trust us for their back tooth implants. Fast shipping, great support, and the best science make ASD Dental Lab your best choice.

Footnotes

[^1]: Based on testing of Grade 5 titanium-zirconia hybrid abutments with industry-standard protocols [^3]: Compatible with major CAD/CAM systems including 3Shape and CEREC

Experience faster turnaround times with our cutting-edge technology

Experience faster turnaround times with our cutting-edge technology